사출 블로우 몰딩 머신

IBM 기계용 작업장 요구 사항: 전력, 공간 및 환경 기준

Aibim, a Wanplas factory with more than 12 years of experience in plastic machinery manufacturing, builds three-station, one-step injection blow molding (IBM) machines for containers from 3 ml to 1000 ml. Aibim runs its own CNC machining center for machine parts, moved into a newly purchased factory in 2022, and holds an annual production capacity of more than 100 machines. Many buyers focus on the machine specification alone, yet the workshop around the machine decides whether that specification is actually delivered every shift. This guide explains the power, space, cooling, compressed-air, and environmental standards an IBM workshop must meet, and it gives a practical pre-installation checklist you can apply before the machine arrives.

Injection blow molding is a one-step process: the resin is plasticized in the barrel, injected to form a parison in the injection cavity, transferred to the blow station, and expanded against the blow mold, then ejected. Because the parison and bottle are handled in a closed, oriented system, IBM naturally produces bottles with a consistent neck finish and no flash, which is why it suits pharmaceutical, oral-liquid, eye-drop, cosmetic, and health-supplement containers. The trade-off is that the process depends on stable utilities. A voltage dip, a warm cooling supply, or oily compressed air can quietly erode output and quality. The sections below turn those risks into concrete workshop requirements.

This article is written for plant engineers, project managers, and procurement teams who are laying out a new IBM line or upgrading an existing one. It is deliberately focused on the workshop shell, the utilities, and the conditions to verify before start-up. It does not cover mold design or operator training systems in depth; those are addressed in Aibim’s separate turnkey program. By the end you will have the data to size your electrical supply, reserve the right floor area, specify the chiller and air system, and define the cleanliness level your product legally and commercially requires.

작업장 계획이 IBM 기계 성능을 결정하는 이유

Aibim IBM machines are precise, repeatable systems, but they are only as stable as the environment they sit in. The three-station index table, the servo or hybrid drive, and the mold-temperature balance all assume a steady supply of electricity, cooling water, and clean compressed air. When any of those drift, the symptoms look like machine faults when they are really workshop faults.

Consider cycle consistency. The injection station must hold a tight melt and cavity temperature window to form a uniform parison. If the cooling water creeps from 12 to 20 degrees Celsius because the chiller is undersized, the mold-temperature circuit cannot hold setpoint, the parison cools unevenly, and wall thickness variation grows. The operator then slows the cycle to compensate, and rated output drops. None of this appears as a broken part; it appears as lost bottles per hour.

Consider electrical stability. The servo and variable-displacement hydraulic system react to voltage. Aibim’s PREFILL technology and variable-displacement pump pressurizing method keep the actual running power well below the installed rating, but the drives still need a clean three-phase supply. Harmonics from other shop loads, unbalanced phases, or a weak neutral can trip protective devices or corrupt the PLC logic. A small uninterruptible power supply at the control cabinet removes that risk for a modest cost.

Consider cleanliness. An IBM bottle for eye drops leaves the blow mold as a finished, sealed-neck container. If the surrounding air carries oil mist, fibers, or high particle counts, those contaminants land on the neck and shoulder exactly where the cap must seal. The workshop cleanliness grade is therefore not a nice-to-have for regulated products; it is part of the product specification. The later sections quantify what grade maps to which industry.

작업장 조건은 기계 주변의 간접비가 아닙니다. 이는 기계 사양의 보이지 않는 절반이며, 정격 생산량, 목 정확도 및 용기 청결도가 실제 공장 현장에서 달성되는지 여부를 결정합니다.

전원 공급 시스템: 전압, 부하 및 변압기 용량 선정

전원 공급은 변압기, 케이블 및 보호 장치를 결정하기 때문에 가장 먼저 확정해야 할 항목이며, 이들은 슬래브를 타설한 후에는 변경하기 어렵습니다. Aibim은 현지 전력망에 맞게 IBM 기계를 제작하므로 논의는 필요한 표준에서 시작됩니다.

일반적인 전압 표준 및 Aibim의 처리 방식

Most Aibim IBM machines ship for three-phase 380 to 415 V at 50 Hz, which covers China, most of Asia, the Middle East, and parts of Europe. The same machine platform can be rewound and re-controlled for 220 to 240 V or 480 V at 60 Hz for the Americas, and for 200 V at 60 Hz for Japan. Confirm the regional standard at order time so the motor terminals, contactors, and the transformer in the control cabinet are correct. A mismatch is not a field fix.

Grid standard Voltage Frequency Phase Typical regions
Default Aibim build 380 to 415 V 50 Hz 3-phase China, Asia, Middle East, parts of Europe
Americas low-voltage 220 to 240 V 60 Hz 3-phase Parts of North and South America
Americas high-power 480 V 60 Hz 3-phase North America heavy supply
Japan 200 V 60 Hz 3-phase Japan

설치 전력 대 실제 운전 전력

The nameplate installed power is the worst-case sum of every motor and heater at full draw. In practice the IBM process never draws all of that at once. The servo or hybrid drive accelerates the index table and clamp only when needed, and the PREFILL hydraulic system only pumps the flow the stroke demands. The actual running power therefore sits at roughly 55 to 75 percent of installed power during normal production. For planning, size the supply on installed power plus the ancillaries, but expect the meter to read lower in steady state.

변압기 용량 및 동시율

A single machine is rarely the only load. Around an IBM line you also run a chiller, a mold-temperature controller, a compressed-air compressor, a resin dryer, conveyors, and the workshop air conditioning. These do not all peak together, so a simultaneity factor of 0.7 to 0.85 is realistic for the supporting utilities. The transformer capacity is then estimated as:

변압기 kVA ≈ (기계 설치 전력 + 보조 장비 설치 전력) × 동시율 ÷ 역률

With a power factor around 0.85 and a simultaneity factor near 0.8, a single IBM75 plus its chiller and dryer typically needs a transformer in the 80 to 100 kVA band, while a six-machine pharmaceutical line with redundant air and cooling can reach 250 kVA or more. Always confirm the final figure against Aibim’s confirmed machine rating and your local ancillary choices.

케이블, 보호, 접지 및 전력 품질

Select the incoming cable cross-section from the continuous running current with a margin for starting inrush, not from the nameplate alone. The main breaker should be coordinated so it trips on a fault but rides through the brief servo acceleration current. A residual-current device protects personnel on the control and auxiliary circuits. The grounding electrode resistance should be 4 ohms or lower, and the supply voltage should stay within plus or minus 10 percent of nominal; beyond that, drives derate or fault.

Two power-quality issues deserve attention in a shared plant. First, harmonics from variable-frequency drives elsewhere in the building can distort the supply; a line reactor or a harmonic filter at the IBM incoming panel reduces this. Second, three-phase imbalance above a few percent heats motors and skews the drive bus; balance the loads across phases during layout. Finally, place a small UPS or a regulated power module on the PLC and HMI supply so a momentary sag during a nearby start-up does not reset the controller and scrap a parison.

Key electricity points: Confirm regional voltage and frequency at order. Expect actual running power at 55 to 75 percent of installed. Apply a 0.7 to 0.85 simultaneity factor for ancillaries. Keep ground resistance at 4 ohms or below and voltage within plus or minus 10 percent. Put a UPS on the PLC.

작업장 면적 및 기계 배치

바닥 공간은 두 번째로 확정해야 할 결정입니다. 기계 설치 면적은 시작에 불과합니다. 실제 필요한 면적은 설치 면적에 금형 장착, 사출 유닛 서비스, 병 제거 및 소재 이동에 필요한 여유 공간을 더한 것입니다. 이를 과소 산정하면 모든 유지보수 작업이 병목이 됩니다.

간격 및 통로 규칙

Reserve at least 800 to 1200 mm of clear space on the non-opening sides of the machine for service and ventilation, and at least 1500 mm on the mold-opening side so the take-out robot, conveyor, or operator can work and so a mold can be slid out onto a trolley. The rear of the injection unit needs room to pull the screw and barrel for cleaning. Pedestrian aisles should be 1200 mm or wider, and forklift aisles 2500 mm or wider so pallets of resin and finished cartons move without squeezing past the machine.

지원 구역

An IBM cell is more than the machine. Plan a mold storage and maintenance area close to the line but clear of traffic, a raw-material zone with the dryer and loader, a finished-goods and short-term buffer area, and a small quality-control station for wall-thickness and leak checks. Keeping these zones adjacent but separated reduces both walking time and cross-contamination of the bottle neck area.

다중 기계 배치 및 면적 범위

여러 대의 기계를 운영하면 통로와 지원 구역이 공유되므로 기계당 면적이 줄어들지만, 서비스와 열 제거를 위해 기계 간 간격은 여전히 필요합니다. 아래 표는 위의 모든 구역을 포함하여 일반적인 구성에 대한 실용적인 작업장 면적 범위를 제공합니다.

Configuration Machines Recommended workshop area Layout note
Pilot or trial line 1 40 to 60 m² Machine plus mold rack, one material pallet, small buffer
Small production cell 3 120 to 180 m² Shared aisle, central QC and material zone
Dedicated production line 6 240 to 360 m² Two rows with central service corridor, separate clean buffer

Arrange multiple machines in two parallel rows facing a central service corridor when the count reaches six. This keeps utilities runs short, gives each machine a 1500 mm service side, and lets one technician walk the line without crossing forklift paths. Leave the corridor free of stored material; material and finished goods belong in their own zones at the line ends.

바닥, 기초 및 진동 제어

바닥은 기계 중량을 지탱하며 수년간의 인덱싱 사이클 동안 평평하고 안정적으로 유지되어야 합니다. 약하거나 고르지 않은 슬래브는 타이바 정렬이 드리프트하고 인덱스 테이블이 반복성을 잃게 하여 간헐적인 플래시 또는 파리슨 잘못된 전송으로 나타납니다.

슬래브 두께, 등급 및 평탄도

Use a reinforced concrete slab with a thickness and reinforcement grade specified by a structural engineer for the local soil. For the machine weights in this article a standard industrial slab of 150 to 200 mm with mesh and doweled joints is typical, but the engineer should confirm. The finished surface should be flat within a few millimeters over the machine footprint so shimming is minimal. The floor must be oil-resistant and slip-resistant, because hydraulic lines and barrel zones can weep, and operators walk the line with full resin bags.

지지 하중 및 앵커링

The machine weight is about 6.8 to 9.8 tons depending on model, spread over the base so the contact pressure is in the range of 10 to 14 kPa for a normal reinforced slab. If your soil or slab is marginal, thicken the local pad under each machine. Most Aibim IBM machines are stabilized with leveling feet and can run without permanent anchor bolts for straightforward installations, but anchor bolts are recommended where the floor is soft, where the machine sits on an upper level, or where local code requires seismic restraint. Discuss anchoring with Aibim when you share the workshop drawings.

진동 및 차단

The IBM process is low-vibration compared with high-tonnage presses, yet the index table and clamp still transmit pulses. If the machine sits near precision measurement equipment or on a flexible upper floor, place elastomer or spring isolation pads under the feet to protect both the machine and the neighbor. Keep the machine away from heavy stamping or grinding nearby that shares the same slab, because transmitted vibration degrades parison transfer accuracy over time.

설치를 위한 천장 높이 및 리프팅

천장 높이는 잊기 쉽고 고치기엔 비쌉니다. 기계 높이는 일부일 뿐입니다. 호퍼, 진공 로더, 리프팅 경로가 나머지를 더합니다.

내부 유효 높이

Plan a clear internal height that exceeds the machine height plus the hopper and loader, which usually means about 3.2 to 3.6 meters from finished floor to the lowest obstruction. If you run a central feeding system with silos above the line, add the silo and pipe height. Do not let ductwork, sprinkler branches, or lighting sit so low that the loader cannot be removed for service.

리프팅 및 접근 경로

Provide a hoist or an overhead crane sized for the machine weight, or at minimum a mobile gantry rated for it, so the machine and heavy molds can be set and later removed. The door and the approach corridor from the truck to the machine position must clear the crate width and height; for a 3.6 m long machine the door should be at least 2.4 m wide and 2.8 m high, and the path must turn without a tight radius that traps the crate. Map the unloading, lifting, and final set points on the workshop drawing before the delivery date.

냉각 시스템: 칠러, 수질 및 금형 온도

냉각은 가장 자주 과소 설계되는 유틸리티이며 사이클 속도를 가장 직접적으로 제한하는 요소입니다. IBM 기계는 유압 오일, 금형 온도 회로 및 배럴과 가소화 구역에서 열을 방출합니다. 세 가지를 모두 잘 냉각하면 기계는 설정값을 유지하고 빠르게 작동합니다.

칠러 용량 및 공급 온도

Size the chiller from total heat rejection, which is roughly the actual running power plus a margin for the dryer and ancillaries. Aibim specifies a cooling-water flow per model, from about 18 L/min on the IBM55 Hybrid to about 30 L/min on the IBM75, at a supply temperature of 8 to 15 degrees Celsius. Use the lower end of that range for high-cycle pharmaceutical work and the upper end for general daily-chemical production. Always insulate the supply and return lines so the set temperature reaches the mold rather than the surrounding air.

수질

Closed-loop cooling water should be controlled for pH, hardness, and conductivity to protect the mold channels and the chiller heat exchanger. A practical window is pH 7.0 to 8.5, low hardness to limit scaling, and controlled conductivity to limit corrosion. Treat and filter the loop, and test it periodically; a fouled mold channel is a slow, invisible cycle-killer. For open cooling towers, use biocide and side-stream filtration and keep the tower away from the air intake of the clean zone.

금형 온도 및 동결 방지

The injection and blow molds are held on their own temperature loops, often with separate zones for the core and cavity. A dedicated mold-temperature controller per machine, or a zoned central unit, keeps each cavity within its narrow window. In cold climates, drain or glycol-treat the loop and insulate the pipes so a weekend shutdown does not burst a line. Keep the chiller and the mold-temperature unit in a ventilated plant area, not inside the clean zone, to avoid dumping their heat into the controlled environment.

압축 공기: 압력, 순도 및 분배

블로우 기능은 IBM 기계가 압축 공기를 필요로 하는 유일한 곳이며, 규제 대상 제품의 경우 공기 순도는 병 청결도의 일부입니다. 공기 시스템을 편의 시설이 아닌 제품 접촉 설비로 취급하십시오.

압력 및 소비

The blow function normally needs 0.6 to 1.0 MPa, with most Aibim configurations designed around 0.8 MPa. Pneumatic consumption is modest, about 0.4 to 0.6 cubic meters per minute depending on model, because the parison is already formed and only needs expansion. Size the compressor with a receiver tank so pressure stays steady through the blow stroke; a receiver of roughly 0.4 to 1.0 cubic meters is typical depending on the number of machines sharing the ring.

제약 및 식품 접촉용 순도

For pharmaceutical, oral-liquid, and food-contact bottles the air must be oil-free, dried to a dew point of minus 20 to minus 40 degrees Celsius, and filtered to an oil content near 0.01 milligrams per cubic meter, which is the medical-grade threshold. An oil-free compressor is the safe choice here, because even a trace of lubricant aerosol lands on the bottle neck and defeats the clean process. The distribution ring should use corrosion-resistant pipe with a falling slope and drain legs, and the pressure drop from the receiver to the last machine should stay small so every cavity sees the same blow pressure.

오일 프리 컴프레서가 필수인 경우

The judgment rule is simple: if the bottle touches a regulated product, specify oil-free air. For purely non-contact daily-chemical packs made in a general workshop, a quality filtered lubricated compressor may be acceptable, but many plants standardize on oil-free to keep one air spec across all lines. Aibim can advise the grade that matches your product and market; the safest path is to plan oil-free from the start.

환경 온도, 습도 및 청정도

기계 주변의 공기는 두 가지 역할을 합니다. 작업자와 전자 장치를 보호하고, 규제 제품의 경우 병을 보호합니다. 필요한 표준은 무엇을 충전하는지에 따라 달라집니다.

온도 및 습도 기준선

Keep the workshop at 18 to 28 degrees Celsius and relative humidity at 45 to 65 percent. This band protects the PLC and drives, keeps the resin dryer efficient, and limits static that attracts dust to the bottle shoulder. Outside this band, the hydraulic oil viscosity shifts, the dryer works harder, and condensation risk on cold mold surfaces rises.

업계별 청정도 등급

For cosmetic vials and daily-chemical small packs, a general, well-ventilated, and regularly cleaned workshop is usually enough. For pharmaceutical bottles, eye-drop vials, and oral-liquid bottles in regulated markets, plan a controlled environment aligned with ISO 14644 Class 8 thinking and a Grade D clean-area concept. That means positive pressure of about 5 to 10 Pa relative to surrounding spaces, a defined number of air changes per hour, and filtration through pre, fine, and high-efficiency stages. The bottle-forming and ejection area is kept cleaner than the general corridor, with separate gowning and buffer rooms so people and material enter through filtered transitions rather than straight from the plant.

청결도는 기계가 아니라 제품에 따라 등급이 매겨집니다. IBM75는 샴푸 포장용 일반 작업장에서 또는 점안액용 Grade D 클린 구역 내에서 가동될 수 있습니다. 작업장 등급은 병의 최종 용도에 따른 속성이며, 슬래브를 타설하기 전에 확정되어야 합니다.

The relative investment for the environment rises from general ventilation through filtered clean zones to full Grade D clean-area construction with air handling and monitoring. Treat it as Low for general daily-chemical work, Medium for a filtered and temperature-controlled room, High for an ISO Class 8 style clean zone, Very High for a Grade D clean area with air handling and monitoring, and Premium for redundant systems with full environmental qualification. Choose the lowest grade that satisfies your market and product, then hold it with discipline.

환기, 방열 및 소음 제어

기계와 보조 장비는 냉각 루프가 포착하지 못하는 열을 방출합니다. 이 열은 냉방 부하가 되며, 무시하면 실내 온도를 28도 상한선 이상으로 끌어올립니다.

열부하 및 공조

Estimate the room cooling load from the machine running power plus the chiller and compressor reject plus solar and people loads. A single IBM line can reject several kilowatts into the room even after the closed cooling loop carries the mold and oil heat away, because the dryer, the control cabinet, and the hydraulic losses all land in the air. Provide general ventilation with filtered make-up air, and add local exhaust at the dryer and the resin feed if dust or odor is present. In a clean zone, the air-handling unit does this work as part of the cleanliness design.

소음

Aibim IBM machines are relatively quiet because the hybrid and servo systems replace much of the hydraulic pump noise, and the process has no high-pressure parison burst. Typical operating noise is below 80 dB(A) at the operator position. If the line sits in a shared or office-adjacent space, enclose the compressor and the chiller remotely and use acoustic screens around the plant room; the machine itself rarely needs screening.

원자재 취급 및 보관

수지 품질과 보관은 병 투명성과 목 청결도에 직접적인 영향을 미칩니다. 작업장 계획은 건조하고 깨끗한 수지를 공정 먼지와 완제품과 분리해야 합니다.

공급, 건조 및 중앙 시스템

Two feeding styles are common. A single machine can use its own hopper loader and dryer beside the injection unit, which is simple and flexible. Several machines can share a central feeding system with a silo and distributed dryers, which saves floor space and standardizes moisture control. For hygroscopic resins the dryer must reach the resin’s target moisture before the barrel, because the IBM parison is thin and intolerant of steam bubbles that become silver streaks.

보관 규율

Keep resin off the floor on pallets, in a dry area away from the loading dock where humidity enters, and protected from pests and direct sunlight. Use first-in-first-out rotation so older lots run first and lot traceability stays clean, which matters for pharmaceutical and food-contact documentation. Separate approved resin from holds and rejects, and keep the layout tidy so the neck-finishing area is never downwind of an open resin bag.

안전 및 화재 예방

Safety is built into the machine and into the room. Aibim machines follow CE-aligned guarding with an interlocked safety door, a light curtain at the operator side, and a long-distance digital laser sensor at the stripper station to confirm the mold is clear before the next index. The workshop must match that discipline.

기계 및 인력 안전

Wire a clearly marked emergency stop within reach of the operator and at the main panel. Keep the safety door interlock and the light curtain functional and never bypass them for production speed. Guard the index table and the ejector with fixed fencing so hands cannot enter the moving zone. Train every operator on the lockout-tagout sequence before any barrel pull or mold change, and post the procedure at the line.

화재, 대피 및 위험물 보관

Divide the workshop into fire compartments sized to the local code, place the correct class and count of extinguishers on mapped points, and keep escape routes lit and unobstructed at all times. Store purge material, lubricants, and cleaning solvents in a dedicated, ventilated cabinet away from the electrical panel and the resin. Keep the main electrical switch accessible and labeled, and rehearse the evacuation plan with the line team so a real alarm is routine rather than confusing.

Aibim IBM 기계 시리즈 및 작업장 관련 사양

The Aibim range covers three models, each a three-station, one-step IBM machine with the PREFILL hydraulic system and CE-aligned safety. The figures below are typical engineering reference values for workshop planning; the confirmed figures are provided by Aibim against your final configuration and mold. They are listed because these are the numbers your electrician, your civil engineer, and your chiller supplier actually need.

IBM75 사출 블로우 성형기

IBM75는 세 가지 중 가장 크며 건강 보조 식품 병과 대형 일용 화학 제품 팩을 포함한 약 50~1000ml의 용기에 적합합니다. 이 제품은 이 범위에서 가장 높은 클램핑력과 가장 넓은 금형 윈도우를 제공합니다.

Parameter IBM75 (reference)
클램핑 포스75 ton class (about 750 kN)
Container range50 to 1000 ml
Installed powerabout 32 kW
Actual running powerabout 20 kW
Dimensions (L × W × H)3600 × 1850 × 2200 mm
기계 무게about 9800 kg
Floor load requirementabout 14 kPa
Cooling water flowabout 30 L/min
Cooling water temperature8 to 15 °C
Compressed air consumptionabout 0.6 m³/min
Compressed air pressure0.8 MPa

IBM65 사출 블로우 성형기

IBM65는 약 10~500ml의 용기에 적합하며, 중간 범위 용량의 경구 액제, 제약 및 화장품 병에 일반적인 선택입니다. 컴팩트한 셀을 위해 설치 면적과 생산량의 균형을 맞춥니다.

Parameter IBM65 (reference)
클램핑 포스65 ton class (about 650 kN)
Container range10 to 500 ml
Installed powerabout 26 kW
Actual running powerabout 16 kW
Dimensions (L × W × H)3300 × 1650 × 2100 mm
기계 무게about 8200 kg
Floor load requirementabout 12 kPa
Cooling water flowabout 24 L/min
Cooling water temperature8 to 15 °C
Compressed air consumptionabout 0.5 m³/min
Compressed air pressure0.8 MPa

IBM55 하이브리드 전동 사출 블로우 성형기

The IBM55 hybrid electric is the most compact and the most energy-efficient of the range, suited to small containers from 3 to 250 ml such as eye-drop vials and miniature cosmetic vials. The hybrid drive pairs electric indexing and clamp motion with a PREFILL hydraulic core, which is why its actual running power is the lowest in the lineup.

Parameter IBM55 Hybrid (reference)
클램핑 포스55 ton class (about 550 kN)
Container range3 to 250 ml
Installed powerabout 22 kW
Actual running powerabout 12 kW
Dimensions (L × W × H)3000 × 1500 × 2000 mm
기계 무게about 6800 kg
Floor load requirementabout 10 kPa
Cooling water flowabout 18 L/min
Cooling water temperature8 to 15 °C
Compressed air consumptionabout 0.4 m³/min
Compressed air pressure0.8 MPa

All three share the same three-station, one-step principle and the same utility pattern; they differ in clamping force, container range, and the floor and power they require. For matched auxiliary equipment such as chillers and mold-temperature controllers, Wanplas can supply coordinated units so the whole cell is specified from one source and the cooling and air numbers above are met consistently.

적용 산업 및 청정도 수준

최종 제품이 작업장 등급을 결정하므로 일반적인 IBM 응용 분야를 필요한 환경에 매핑하는 것이 가치가 있습니다. Aibim IBM 기계는 의약품, 식품 및 음료, 화장품 시장에 서비스를 제공하며, 용기 크기는 3ml~1000ml에 걸쳐 있습니다.

제약 및 의료

Pharmaceutical bottles, oral-liquid bottles, and eye-drop vials are the strictest case. Eye-drop vials in the 3 to 30 ml range are typically run on the IBM55 Hybrid inside a Grade D clean area with oil-free air and filtered make-up air, because the drop must stay sterile at the neck. Oral-liquid and general pharmaceutical bottles in the 30 to 150 ml range are usually run on the IBM65 under the same cleanliness thinking. The neck finish from IBM is precise and flash-free, which helps the cap seal, but the surrounding air must not contaminate that finish.

화장품 및 퍼스널케어

Cosmetic vials and small personal-care jars from about 10 to 100 ml are run on the IBM55 or IBM65. Cosmetic plants often choose a filtered, temperature-controlled room rather than a full Grade D clean area, because the product is not sterile but the brand still demands a clean, glossy shoulder with no particles. The IBM process suits this well because the bottle is handled in an oriented, enclosed transfer rather than dropped on a belt.

건강 보조 식품 및 일상 화학 제품

Health-supplement bottles from about 100 to 1000 ml are a natural fit for the IBM75, often in a general but tidy workshop with good ventilation. Daily-chemical small packs such as shampoo and lotion sample bottles are similar: the grade is general, the priority is output and neck consistency, and the air system can be a quality filtered compressor rather than oil-free medical-grade. The difference between these industries is therefore not the machine but the cleanliness discipline around it.

모델 요구 사항 및 작업장 구성표

The table below links a typical requirement to a recommended Aibim model, the machine count, the cleanliness grade, and the resulting workshop area, power, cooling, and air configuration. Use it as a starting layout, then refine the numbers with Aibim against your confirmed machine ratings and local ancillaries.

Requirement scenario Recommended model Units Cleanliness grade Workshop area Power supply Cooling and air
Eye-drop vials 3 to 30 ml, high volume IBM55 Hybrid 6 ISO Class 8 / Grade D 300 to 360 m² 250 kVA transformer 2 chillers about 20 kW; 2 oil-free receivers about 1 m³ at 0.8 MPa
Oral-liquid and pharma bottles 30 to 150 ml IBM65 3 ISO Class 8 / Grade D 150 to 180 m² 160 kVA transformer 1 chiller about 25 kW; 1 oil-free receiver about 0.6 m³
Cosmetic vials 10 to 100 ml IBM65 / IBM55 3 Filtered, temp-controlled 120 to 160 m² 125 kVA transformer 1 chiller about 20 kW; 1 receiver about 0.6 m³
Daily-chemical small packs 50 to 500 ml IBM75 1 to 3 General ventilation 60 to 160 m² 80 to 160 kVA 1 chiller 15 to 30 kW; receiver about 0.6 m³
Health-supplement bottles 100 to 1000 ml IBM75 3 General, Grade D optional 150 to 180 m² 160 kVA transformer 1 chiller about 30 kW; receiver about 0.6 m³

This table intentionally separates the machine choice from the workshop grade. Two plants making the same bottle on the same IBM65 can need very different areas and air specs because one ships to a regulated market and the other does not. Set the grade from the product, then size the room and utilities to that grade.

최초 가동 전 사전 설치 체크리스트

The single most useful document for a smooth commissioning is a pre-installation checklist completed before the truck arrives. Aibim reviews your workshop drawings against this checklist, and the Yes-No columns below are the ones to verify on site. Resolve every No before start-up; a missing ground or a weak chiller turns a one-day commissioning into a two-week delay.

Category Check item Target Yes / No
ElectricalCorrect regional voltage and frequency supplied380 to 415 V 50 Hz or as ordered
ElectricalTransformer and cable sized for installed plus ancillariesPer Aibim confirmed rating
ElectricalGround resistance measured4 ohms or below
ElectricalUPS on PLC and HMI supplyFitted
WaterChiller capacity matches total heat rejection8 to 15 °C supply
WaterFlow per machine available at the inlet18 to 30 L/min per model
WaterLoop water quality controlledpH 7.0 to 8.5, low hardness
AirBlow pressure at the ring0.8 MPa stable
AirPurity for product contactOil-free, dew point minus 20 to minus 40 °C, 0.01 mg/m³ oil
FloorSlab strength and flatness10 to 14 kPa, flat surface
FloorOil-resistant, slip-resistant finishConfirmed
SpaceSide and mold-opening clearance800 to 1200 mm sides, 1500 mm opening
SpaceClear ceiling height and lifting path3.2 to 3.6 m, hoist or crane sized
EnvironmentTemperature and humidity18 to 28 °C, 45 to 65 percent RH
EnvironmentCleanliness grade built where requiredISO Class 8 / Grade D if regulated
PersonnelTrained operator and lockout knowledgeTraining completed
PersonnelEmergency stop and escape route verifiedMarked and clear

출하 전에 완성된 체크리스트를 Aibim에 전달하십시오. 이는 설치와 시운전을 단축하고 일반적인 예상치 못한 문제를 방지하며, 작업장이 인도하기로 약속한 내용에 대한 서명된 기준을 양측에 제공합니다.

원활한 시운전을 위한 서비스 및 지원

Wanplas 공장인 Aibim은 그룹의 공동 서비스 약속으로 기계를 지원하므로, 위의 작업장 계획은 인도 후 지원과 함께 이루어집니다. 목표는 라인이 정격 생산량에 빠르게 도달하고 그 수준을 유지하는 것입니다.

납품 전 및 납품 중

Every machine is tested before shipment so the utilities and the process are verified at the factory, not discovered at your site. Aibim reviews your workshop drawings and the pre-installation checklist, then dispatches engineers for installation and commissioning on site. Because Aibim runs its own CNC machining center, critical parts are made and matched in-house, which shortens lead time and keeps the spare-part fit precise.

예비 부품, 교육 및 원격 지원

The Wanplas group policy supplies USD 500 free parts every year, and warranty covers defective parts within the agreed period. Aibim trains your operators and maintenance staff on the line, the mold change, and the lockout procedure, and offers remote monitoring of the PLC so faults can be analyzed from the factory without a long on-site wait. The open-factory policy welcomes you to visit the 2022 plant, see the CNC center, and inspect the workshop-standard machines before you commit.

가동 전 워크숍 검토

As part of commissioning, Aibim conducts a pre-start workshop condition review using the same seven categories in the checklist above: electrical, water, air, floor, space, environment, and personnel. This is the moment to catch a borderline ground, a slightly small chiller, or a missing oil-free air spec before production begins. Treat it as the final gate between a delivered machine and a running line.

자주 묻는 질문(FAQ)

Aibim IBM 기계에는 어떤 전원 공급이 필요하나요?

Most Aibim IBM machines are built for three-phase 380 to 415 V at 50 Hz, which is the default for China, much of Asia, and parts of Europe. The machines can also be configured for 220 to 240 V or 480 V at 60 Hz for the Americas and for 200 V at 60 Hz for Japan. The installed power ranges from about 22 kW on the IBM55 Hybrid up to about 32 kW on the IBM75, while the actual running load sits at roughly 55 to 75 percent of installed power because servo drives and the PREFILL hydraulic system do not draw full current continuously.

IBM 기계 한 대에 필요한 바닥 공간은 얼마인가요?

A single IBM machine needs about 40 to 60 square meters of workshop area when you include the machine footprint, operator and maintenance clearance of at least 800 to 1200 mm on the sides and 1500 mm at the mold-opening side, plus space for a small mold rack, a raw-material pallet, and finished-goods staging. Three machines typically need 120 to 180 square meters, and a six-machine line needs roughly 240 to 360 square meters once you add aisles, quality control, and buffer storage.

IBM 병에 클린룸이 필요한가요?

It depends on the end use. Cosmetic vials and daily-chemical small packs can be made in a general, well-ventilated workshop. Pharmaceutical bottles, eye-drop vials, and oral-liquid bottles for regulated markets usually require a controlled environment aligned with ISO 14644 Class 8 thinking and a Grade D clean-area concept, with positive pressure of about 5 to 10 Pa, controlled temperature and humidity, and filtered air. Aibim can advise the grade that matches your product and market.

블로우 기능에는 어떤 압축 공기 압력과 품질이 필요합니까?

The blow function on an IBM machine normally needs 0.6 to 1.0 MPa, with most Aibim configurations designed around 0.8 MPa. Pneumatic consumption is modest, about 0.4 to 0.6 cubic meters per minute depending on model. For pharmaceutical and food-contact products the air should be oil-free, dried to a dew point of minus 20 to minus 40 degrees Celsius, and filtered to an oil content near 0.01 milligrams per cubic meter, which is the medical-grade threshold.

PREFILL 유압 시스템이 내 공장 전력 계획과 왜 관련이 있습니까?

Aibim uses a PREFILL technology and variable-displacement pump pressurizing method in the hydraulic circuit. This means the pump only delivers the flow the process needs at each moment, so the actual running power stays well below the installed rating. That lowers the transformer and cable size you must provision and reduces heat rejected into the workshop, which in turn reduces the air-conditioning load.

인도 전에 Aibim이 제 작업장을 검증하는 데 도움을 줄 수 있나요?

Yes. Aibim runs a pre-installation checklist covering power, water, air, floor, space, environment, and personnel, and reviews your workshop drawings before shipment. The factory also performs testing before delivery, provides installation and commissioning, supplies USD 500 free parts every year, trains operators, offers remote monitoring of the PLC, and welcomes an open-factory visit so you can inspect the workshop-standard machines directly.

IBM 라인에는 어떤 냉각 용량을 계획해야 하나요?

Cooling serves the hydraulic oil, the mold-temperature circuits, and the barrel and plasticizing zones. Aibim specifies cooling-water flow per model, from about 18 L/min on the IBM55 Hybrid to about 30 L/min on the IBM75, at a supply temperature of 8 to 15 degrees Celsius. Size the chiller from the total heat rejection, which is roughly the running power plus a margin for the dryer and ancillaries, and always insulate the supply and return lines to protect the set temperature.

IBM 기계에는 어떤 바닥 강도와 천장 높이가 필요합니까?

The machine weight is about 6.8 to 9.8 tons depending on model, spread over a footprint so the floor loading is in the range of 10 to 14 kPa for a standard reinforced concrete slab. The floor should be flat, oil-resistant, and slip-resistant. The clear internal height should exceed the machine height plus the hopper and loader, usually about 3.2 to 3.6 meters, with a lifting device such as a hoist or overhead crane sized for the machine weight to handle unloading and mold changes.

결론

Aibim, a Wanplas factory with more than 12 years of plastic machinery experience, its own CNC machining center, a 2022 new plant, and an annual capacity above 100 machines, builds three-station, one-step IBM machines for containers from 3 ml to 1000 ml. The machine is only half of the result; the workshop around it decides whether the rated output, the precise neck finish, and the required cleanliness are actually achieved. This guide has covered the power supply from voltage standard to transformer sizing, the floor area and layout from single cell to six-machine line, the floor and foundation, the ceiling and lifting, the cooling and compressed-air systems, the temperature and cleanliness grades by industry, ventilation and noise, material handling, and safety, closing with the model and configuration table, the pre-installation checklist, and the service that backs it all.

If you are planning a new IBM line or upgrading an existing one, send Aibim your workshop drawings and your target products. The engineering team will review the layout, confirm the model choice between the IBM75, IBM65, and IBM55 Hybrid, and return a utility and workshop configuration proposal covering power, cooling, air, floor, and cleanliness so your line starts up fast and stays stable. Aibim welcomes a visit to the factory to walk through the machines and the standards described here before you place the order.