Aibim, a Wanplas factory with more than 12 years of experience in plastic machinery manufacturing, builds three-station, one-step injection blow molding (IBM) machines for containers from 3 ml to 1000 ml. Aibim runs its own CNC machining center for machine parts, moved into a newly purchased factory in 2022, and holds an annual production capacity of more than 100 machines. Many buyers focus on the machine specification alone, yet the workshop around the machine decides whether that specification is actually delivered every shift. This guide explains the power, space, cooling, compressed-air, and environmental standards an IBM workshop must meet, and it gives a practical pre-installation checklist you can apply before the machine arrives.
Injection blow molding is a one-step process: the resin is plasticized in the barrel, injected to form a parison in the injection cavity, transferred to the blow station, and expanded against the blow mold, then ejected. Because the parison and bottle are handled in a closed, oriented system, IBM naturally produces bottles with a consistent neck finish and no flash, which is why it suits pharmaceutical, oral-liquid, eye-drop, cosmetic, and health-supplement containers. The trade-off is that the process depends on stable utilities. A voltage dip, a warm cooling supply, or oily compressed air can quietly erode output and quality. The sections below turn those risks into concrete workshop requirements.
This article is written for plant engineers, project managers, and procurement teams who are laying out a new IBM line or upgrading an existing one. It is deliberately focused on the workshop shell, the utilities, and the conditions to verify before start-up. It does not cover mold design or operator training systems in depth; those are addressed in Aibim’s separate turnkey program. By the end you will have the data to size your electrical supply, reserve the right floor area, specify the chiller and air system, and define the cleanliness level your product legally and commercially requires.
Perché la pianificazione dell'officina determina le prestazioni delle macchine IBM
Aibim IBM machines are precise, repeatable systems, but they are only as stable as the environment they sit in. The three-station index table, the servo or hybrid drive, and the mold-temperature balance all assume a steady supply of electricity, cooling water, and clean compressed air. When any of those drift, the symptoms look like machine faults when they are really workshop faults.
Consider cycle consistency. The injection station must hold a tight melt and cavity temperature window to form a uniform parison. If the cooling water creeps from 12 to 20 degrees Celsius because the chiller is undersized, the mold-temperature circuit cannot hold setpoint, the parison cools unevenly, and wall thickness variation grows. The operator then slows the cycle to compensate, and rated output drops. None of this appears as a broken part; it appears as lost bottles per hour.
Consider electrical stability. The servo and variable-displacement hydraulic system react to voltage. Aibim’s PREFILL technology and variable-displacement pump pressurizing method keep the actual running power well below the installed rating, but the drives still need a clean three-phase supply. Harmonics from other shop loads, unbalanced phases, or a weak neutral can trip protective devices or corrupt the PLC logic. A small uninterruptible power supply at the control cabinet removes that risk for a modest cost.
Consider cleanliness. An IBM bottle for eye drops leaves the blow mold as a finished, sealed-neck container. If the surrounding air carries oil mist, fibers, or high particle counts, those contaminants land on the neck and shoulder exactly where the cap must seal. The workshop cleanliness grade is therefore not a nice-to-have for regulated products; it is part of the product specification. The later sections quantify what grade maps to which industry.
Le condizioni dell'officina non sono un costo generale intorno alla macchina. Sono la metà invisibile della specifica della macchina e determinano se la produzione nominale, la precisione del collo e la pulizia del contenitore vengono effettivamente raggiunte sul pavimento della fabbrica.
Sistema di alimentazione: tensione, carico e dimensionamento del trasformatore
L'alimentazione elettrica è il primo elemento da definire, perché determina il trasformatore, il cavo e i dispositivi di protezione, ed è difficile modificarli dopo il getto della soletta. Aibim costruisce macchine IBM adatte alla rete locale, quindi la discussione inizia con lo standard di cui avete bisogno.
Standard di tensione comuni e come Aibim li gestisce
Most Aibim IBM machines ship for three-phase 380 to 415 V at 50 Hz, which covers China, most of Asia, the Middle East, and parts of Europe. The same machine platform can be rewound and re-controlled for 220 to 240 V or 480 V at 60 Hz for the Americas, and for 200 V at 60 Hz for Japan. Confirm the regional standard at order time so the motor terminals, contactors, and the transformer in the control cabinet are correct. A mismatch is not a field fix.
| Grid standard | Voltage | Frequency | Phase | Typical regions |
|---|---|---|---|---|
| Default Aibim build | 380 to 415 V | 50 Hz | 3-phase | China, Asia, Middle East, parts of Europe |
| Americas low-voltage | 220 to 240 V | 60 Hz | 3-phase | Parts of North and South America |
| Americas high-power | 480 V | 60 Hz | 3-phase | North America heavy supply |
| Japan | 200 V | 60 Hz | 3-phase | Japan |
Potenza installata vs potenza effettiva in esercizio
The nameplate installed power is the worst-case sum of every motor and heater at full draw. In practice the IBM process never draws all of that at once. The servo or hybrid drive accelerates the index table and clamp only when needed, and the PREFILL hydraulic system only pumps the flow the stroke demands. The actual running power therefore sits at roughly 55 to 75 percent of installed power during normal production. For planning, size the supply on installed power plus the ancillaries, but expect the meter to read lower in steady state.
Capacità del trasformatore e fattore di simultaneità
A single machine is rarely the only load. Around an IBM line you also run a chiller, a mold-temperature controller, a compressed-air compressor, a resin dryer, conveyors, and the workshop air conditioning. These do not all peak together, so a simultaneity factor of 0.7 to 0.85 is realistic for the supporting utilities. The transformer capacity is then estimated as:
kVA del trasformatore ≈ (potenza installata della macchina + potenza installata degli ausiliari) × fattore di contemporaneità ÷ fattore di potenza
With a power factor around 0.85 and a simultaneity factor near 0.8, a single IBM75 plus its chiller and dryer typically needs a transformer in the 80 to 100 kVA band, while a six-machine pharmaceutical line with redundant air and cooling can reach 250 kVA or more. Always confirm the final figure against Aibim’s confirmed machine rating and your local ancillary choices.
Cavi, protezione, messa a terra e qualità dell'alimentazione
Select the incoming cable cross-section from the continuous running current with a margin for starting inrush, not from the nameplate alone. The main breaker should be coordinated so it trips on a fault but rides through the brief servo acceleration current. A residual-current device protects personnel on the control and auxiliary circuits. The grounding electrode resistance should be 4 ohms or lower, and the supply voltage should stay within plus or minus 10 percent of nominal; beyond that, drives derate or fault.
Two power-quality issues deserve attention in a shared plant. First, harmonics from variable-frequency drives elsewhere in the building can distort the supply; a line reactor or a harmonic filter at the IBM incoming panel reduces this. Second, three-phase imbalance above a few percent heats motors and skews the drive bus; balance the loads across phases during layout. Finally, place a small UPS or a regulated power module on the PLC and HMI supply so a momentary sag during a nearby start-up does not reset the controller and scrap a parison.
Area dell'officina e disposizione della macchina
Lo spazio a pavimento è la seconda decisione fissa. L'ingombro della macchina è solo l'inizio; l'area reale è l'ingombro più lo spazio libero necessario per caricare gli stampi, fare manutenzione all'unità di iniezione, rimuovere le bottiglie e movimentare il materiale. Se lo sottodimensionate, ogni attività di manutenzione diventa un collo di bottiglia.
Regole per spazi liberi e corridoi
Reserve at least 800 to 1200 mm of clear space on the non-opening sides of the machine for service and ventilation, and at least 1500 mm on the mold-opening side so the take-out robot, conveyor, or operator can work and so a mold can be slid out onto a trolley. The rear of the injection unit needs room to pull the screw and barrel for cleaning. Pedestrian aisles should be 1200 mm or wider, and forklift aisles 2500 mm or wider so pallets of resin and finished cartons move without squeezing past the machine.
Zone di supporto
An IBM cell is more than the machine. Plan a mold storage and maintenance area close to the line but clear of traffic, a raw-material zone with the dryer and loader, a finished-goods and short-term buffer area, and a small quality-control station for wall-thickness and leak checks. Keeping these zones adjacent but separated reduces both walking time and cross-contamination of the bottle neck area.
Layout multi-macchina e intervalli di area
Quando gestite più macchine, l'area per macchina diminuisce perché corridoi e zone di supporto sono condivisi, ma avete comunque bisogno di spazio tra le macchine per la manutenzione e lo smaltimento del calore. La tabella seguente fornisce intervalli pratici di area di officina per configurazioni comuni, incluse tutte le zone sopra indicate.
| Configuration | Machines | Recommended workshop area | Layout note |
|---|---|---|---|
| Pilot or trial line | 1 | 40 to 60 m² | Machine plus mold rack, one material pallet, small buffer |
| Small production cell | 3 | 120 to 180 m² | Shared aisle, central QC and material zone |
| Dedicated production line | 6 | 240 to 360 m² | Two rows with central service corridor, separate clean buffer |
Arrange multiple machines in two parallel rows facing a central service corridor when the count reaches six. This keeps utilities runs short, gives each machine a 1500 mm service side, and lets one technician walk the line without crossing forklift paths. Leave the corridor free of stored material; material and finished goods belong in their own zones at the line ends.
Pavimento, fondazione e controllo delle vibrazioni
Il pavimento sopporta il peso della macchina e deve rimanere piatto e stabile per anni di cicli di indicizzazione. Una soletta debole o irregolare causa la deriva dell'allineamento dei tiranti e la perdita di ripetibilità della tavola indicizzatrice, che si manifesta come bava intermittente o trasferimento errato della parison.
Spessore, grado e planarità della piastra
Use a reinforced concrete slab with a thickness and reinforcement grade specified by a structural engineer for the local soil. For the machine weights in this article a standard industrial slab of 150 to 200 mm with mesh and doweled joints is typical, but the engineer should confirm. The finished surface should be flat within a few millimeters over the machine footprint so shimming is minimal. The floor must be oil-resistant and slip-resistant, because hydraulic lines and barrel zones can weep, and operators walk the line with full resin bags.
Capacità portante e ancoraggio
The machine weight is about 6.8 to 9.8 tons depending on model, spread over the base so the contact pressure is in the range of 10 to 14 kPa for a normal reinforced slab. If your soil or slab is marginal, thicken the local pad under each machine. Most Aibim IBM machines are stabilized with leveling feet and can run without permanent anchor bolts for straightforward installations, but anchor bolts are recommended where the floor is soft, where the machine sits on an upper level, or where local code requires seismic restraint. Discuss anchoring with Aibim when you share the workshop drawings.
Vibrazioni e isolamento
The IBM process is low-vibration compared with high-tonnage presses, yet the index table and clamp still transmit pulses. If the machine sits near precision measurement equipment or on a flexible upper floor, place elastomer or spring isolation pads under the feet to protect both the machine and the neighbor. Keep the machine away from heavy stamping or grinding nearby that shares the same slab, because transmitted vibration degrades parison transfer accuracy over time.
Altezza del soffitto e sollevamento per l'installazione
L'altezza del soffitto è facile da dimenticare e costosa da correggere. L'altezza della macchina è solo parte della storia; la tramoggia, il caricatore a vuoto e il percorso di sollevamento aggiungono il resto.
Altezza interna libera
Plan a clear internal height that exceeds the machine height plus the hopper and loader, which usually means about 3.2 to 3.6 meters from finished floor to the lowest obstruction. If you run a central feeding system with silos above the line, add the silo and pipe height. Do not let ductwork, sprinkler branches, or lighting sit so low that the loader cannot be removed for service.
Percorso di sollevamento e accesso
Provide a hoist or an overhead crane sized for the machine weight, or at minimum a mobile gantry rated for it, so the machine and heavy molds can be set and later removed. The door and the approach corridor from the truck to the machine position must clear the crate width and height; for a 3.6 m long machine the door should be at least 2.4 m wide and 2.8 m high, and the path must turn without a tight radius that traps the crate. Map the unloading, lifting, and final set points on the workshop drawing before the delivery date.
Sistema di raffreddamento: chiller, qualità dell'acqua e temperatura dello stampo
Il raffreddamento è l'utilità più spesso sottodimensionata ed è quella che limita più direttamente la velocità del ciclo. Una macchina IBM dissipa calore dall'olio idraulico, dai circuiti di temperatura stampo e dalle zone del cilindro e di plastificazione. Raffreddate bene tutte e tre e la macchina mantiene il setpoint e funziona velocemente.
Capacità del chiller e temperatura di alimentazione
Size the chiller from total heat rejection, which is roughly the actual running power plus a margin for the dryer and ancillaries. Aibim specifies a cooling-water flow per model, from about 18 L/min on the IBM55 Hybrid to about 30 L/min on the IBM75, at a supply temperature of 8 to 15 degrees Celsius. Use the lower end of that range for high-cycle pharmaceutical work and the upper end for general daily-chemical production. Always insulate the supply and return lines so the set temperature reaches the mold rather than the surrounding air.
Qualità dell'acqua
Closed-loop cooling water should be controlled for pH, hardness, and conductivity to protect the mold channels and the chiller heat exchanger. A practical window is pH 7.0 to 8.5, low hardness to limit scaling, and controlled conductivity to limit corrosion. Treat and filter the loop, and test it periodically; a fouled mold channel is a slow, invisible cycle-killer. For open cooling towers, use biocide and side-stream filtration and keep the tower away from the air intake of the clean zone.
Temperatura dello stampo e protezione dal congelamento
The injection and blow molds are held on their own temperature loops, often with separate zones for the core and cavity. A dedicated mold-temperature controller per machine, or a zoned central unit, keeps each cavity within its narrow window. In cold climates, drain or glycol-treat the loop and insulate the pipes so a weekend shutdown does not burst a line. Keep the chiller and the mold-temperature unit in a ventilated plant area, not inside the clean zone, to avoid dumping their heat into the controlled environment.
Aria compressa: pressione, purezza e distribuzione
La funzione di soffiaggio è l'unico punto in cui una macchina IBM ha bisogno di aria compressa, e per i prodotti regolamentati la purezza dell'aria fa parte della pulizia della bottiglia. Trattare il sistema dell'aria come un'utilità a contatto con il prodotto, non come una comodità.
Pressione e consumo
The blow function normally needs 0.6 to 1.0 MPa, with most Aibim configurations designed around 0.8 MPa. Pneumatic consumption is modest, about 0.4 to 0.6 cubic meters per minute depending on model, because the parison is already formed and only needs expansion. Size the compressor with a receiver tank so pressure stays steady through the blow stroke; a receiver of roughly 0.4 to 1.0 cubic meters is typical depending on the number of machines sharing the ring.
Purezza per il contatto farmaceutico e alimentare
For pharmaceutical, oral-liquid, and food-contact bottles the air must be oil-free, dried to a dew point of minus 20 to minus 40 degrees Celsius, and filtered to an oil content near 0.01 milligrams per cubic meter, which is the medical-grade threshold. An oil-free compressor is the safe choice here, because even a trace of lubricant aerosol lands on the bottle neck and defeats the clean process. The distribution ring should use corrosion-resistant pipe with a falling slope and drain legs, and the pressure drop from the receiver to the last machine should stay small so every cavity sees the same blow pressure.
Quando un compressore oil-free è obbligatorio
The judgment rule is simple: if the bottle touches a regulated product, specify oil-free air. For purely non-contact daily-chemical packs made in a general workshop, a quality filtered lubricated compressor may be acceptable, but many plants standardize on oil-free to keep one air spec across all lines. Aibim can advise the grade that matches your product and market; the safest path is to plan oil-free from the start.
Temperatura ambientale, umidità e pulizia
L'aria attorno alla macchina svolge due compiti: protegge l'operatore e l'elettronica e, per i prodotti regolamentati, protegge la bottiglia. Lo standard di cui avete bisogno dipende da cosa riempite.
Valori di riferimento di temperatura e umidità
Keep the workshop at 18 to 28 degrees Celsius and relative humidity at 45 to 65 percent. This band protects the PLC and drives, keeps the resin dryer efficient, and limits static that attracts dust to the bottle shoulder. Outside this band, the hydraulic oil viscosity shifts, the dryer works harder, and condensation risk on cold mold surfaces rises.
Gradi di pulizia per settore
For cosmetic vials and daily-chemical small packs, a general, well-ventilated, and regularly cleaned workshop is usually enough. For pharmaceutical bottles, eye-drop vials, and oral-liquid bottles in regulated markets, plan a controlled environment aligned with ISO 14644 Class 8 thinking and a Grade D clean-area concept. That means positive pressure of about 5 to 10 Pa relative to surrounding spaces, a defined number of air changes per hour, and filtration through pre, fine, and high-efficiency stages. The bottle-forming and ejection area is kept cleaner than the general corridor, with separate gowning and buffer rooms so people and material enter through filtered transitions rather than straight from the plant.
La pulizia è classificata per prodotto, non per macchina. Un IBM75 può operare in un'officina generale per confezioni di shampoo o all'interno di un'area pulita di Grado D per colliri. Il grado dell'officina è una proprietà dell'uso finale della bottiglia e dovrebbe essere fissato prima che la soletta venga gettata.
The relative investment for the environment rises from general ventilation through filtered clean zones to full Grade D clean-area construction with air handling and monitoring. Treat it as Low for general daily-chemical work, Medium for a filtered and temperature-controlled room, High for an ISO Class 8 style clean zone, Very High for a Grade D clean area with air handling and monitoring, and Premium for redundant systems with full environmental qualification. Choose the lowest grade that satisfies your market and product, then hold it with discipline.
Ventilazione, rimozione del calore e controllo del rumore
La macchina e i suoi ausiliari dissipano calore che il circuito di raffreddamento non cattura. Quel calore diventa un carico per il condizionamento dell'aria e, se ignorato, porta la stanza oltre il limite di 28 gradi.
Carico termico e climatizzazione
Estimate the room cooling load from the machine running power plus the chiller and compressor reject plus solar and people loads. A single IBM line can reject several kilowatts into the room even after the closed cooling loop carries the mold and oil heat away, because the dryer, the control cabinet, and the hydraulic losses all land in the air. Provide general ventilation with filtered make-up air, and add local exhaust at the dryer and the resin feed if dust or odor is present. In a clean zone, the air-handling unit does this work as part of the cleanliness design.
Rumore
Aibim IBM machines are relatively quiet because the hybrid and servo systems replace much of the hydraulic pump noise, and the process has no high-pressure parison burst. Typical operating noise is below 80 dB(A) at the operator position. If the line sits in a shared or office-adjacent space, enclose the compressor and the chiller remotely and use acoustic screens around the plant room; the machine itself rarely needs screening.
Movimentazione e stoccaggio delle materie prime
La qualità della resina e la sua conservazione influiscono direttamente sulla chiarezza della bottiglia e sulla pulizia del collo. Il piano del laboratorio dovrebbe separare la resina asciutta e pulita dalla polvere di processo e dai prodotti finiti.
Sistemi di alimentazione, essiccazione e centrali
Two feeding styles are common. A single machine can use its own hopper loader and dryer beside the injection unit, which is simple and flexible. Several machines can share a central feeding system with a silo and distributed dryers, which saves floor space and standardizes moisture control. For hygroscopic resins the dryer must reach the resin’s target moisture before the barrel, because the IBM parison is thin and intolerant of steam bubbles that become silver streaks.
Disciplina dello stoccaggio
Keep resin off the floor on pallets, in a dry area away from the loading dock where humidity enters, and protected from pests and direct sunlight. Use first-in-first-out rotation so older lots run first and lot traceability stays clean, which matters for pharmaceutical and food-contact documentation. Separate approved resin from holds and rejects, and keep the layout tidy so the neck-finishing area is never downwind of an open resin bag.
Sicurezza e protezione antincendio
Safety is built into the machine and into the room. Aibim machines follow CE-aligned guarding with an interlocked safety door, a light curtain at the operator side, and a long-distance digital laser sensor at the stripper station to confirm the mold is clear before the next index. The workshop must match that discipline.
Sicurezza di macchina e personale
Wire a clearly marked emergency stop within reach of the operator and at the main panel. Keep the safety door interlock and the light curtain functional and never bypass them for production speed. Guard the index table and the ejector with fixed fencing so hands cannot enter the moving zone. Train every operator on the lockout-tagout sequence before any barrel pull or mold change, and post the procedure at the line.
Incendio, vie di fuga e stoccaggio di materiali pericolosi
Divide the workshop into fire compartments sized to the local code, place the correct class and count of extinguishers on mapped points, and keep escape routes lit and unobstructed at all times. Store purge material, lubricants, and cleaning solvents in a dedicated, ventilated cabinet away from the electrical panel and the resin. Keep the main electrical switch accessible and labeled, and rehearse the evacuation plan with the line team so a real alarm is routine rather than confusing.
Serie di macchine Aibim IBM e specifiche rilevanti per l'officina
The Aibim range covers three models, each a three-station, one-step IBM machine with the PREFILL hydraulic system and CE-aligned safety. The figures below are typical engineering reference values for workshop planning; the confirmed figures are provided by Aibim against your final configuration and mold. They are listed because these are the numbers your electrician, your civil engineer, and your chiller supplier actually need.
Macchina per stampaggio a iniezione e soffiaggio IBM75
L'IBM75 è la più grande delle tre e si adatta a contenitori da circa 50 a 1000 ml, incluse bottiglie per integratori alimentari e confezioni più grandi per prodotti chimici quotidiani. Ha la forza di chiusura più elevata e la finestra stampo più ampia della gamma.
| Parameter | IBM75 (reference) |
|---|---|
| Forza di chiusura | 75 ton class (about 750 kN) |
| Container range | 50 to 1000 ml |
| Installed power | about 32 kW |
| Actual running power | about 20 kW |
| Dimensions (L × W × H) | 3600 × 1850 × 2200 mm |
| Peso della macchina | about 9800 kg |
| Floor load requirement | about 14 kPa |
| Cooling water flow | about 30 L/min |
| Cooling water temperature | 8 to 15 °C |
| Compressed air consumption | about 0.6 m³/min |
| Compressed air pressure | 0.8 MPa |
Macchina per stampaggio a iniezione e soffiaggio IBM65
L'IBM65 si adatta a contenitori da circa 10 a 500 ml ed è una scelta comune per flaconi per liquidi orali, farmaceutici e cosmetici dove il volume è di fascia media. Bilancia ingombro e produzione per una cella compatta.
| Parameter | IBM65 (reference) |
|---|---|
| Forza di chiusura | 65 ton class (about 650 kN) |
| Container range | 10 to 500 ml |
| Installed power | about 26 kW |
| Actual running power | about 16 kW |
| Dimensions (L × W × H) | 3300 × 1650 × 2100 mm |
| Peso della macchina | about 8200 kg |
| Floor load requirement | about 12 kPa |
| Cooling water flow | about 24 L/min |
| Cooling water temperature | 8 to 15 °C |
| Compressed air consumption | about 0.5 m³/min |
| Compressed air pressure | 0.8 MPa |
Macchina per stampaggio a iniezione e soffiaggio ibrida elettrica IBM55
The IBM55 hybrid electric is the most compact and the most energy-efficient of the range, suited to small containers from 3 to 250 ml such as eye-drop vials and miniature cosmetic vials. The hybrid drive pairs electric indexing and clamp motion with a PREFILL hydraulic core, which is why its actual running power is the lowest in the lineup.
| Parameter | IBM55 Hybrid (reference) |
|---|---|
| Forza di chiusura | 55 ton class (about 550 kN) |
| Container range | 3 to 250 ml |
| Installed power | about 22 kW |
| Actual running power | about 12 kW |
| Dimensions (L × W × H) | 3000 × 1500 × 2000 mm |
| Peso della macchina | about 6800 kg |
| Floor load requirement | about 10 kPa |
| Cooling water flow | about 18 L/min |
| Cooling water temperature | 8 to 15 °C |
| Compressed air consumption | about 0.4 m³/min |
| Compressed air pressure | 0.8 MPa |
All three share the same three-station, one-step principle and the same utility pattern; they differ in clamping force, container range, and the floor and power they require. For matched auxiliary equipment such as chillers and mold-temperature controllers, Wanplas can supply coordinated units so the whole cell is specified from one source and the cooling and air numbers above are met consistently.
Settori applicativi e relativi livelli di pulizia
Il prodotto finale decide il grado dell'officina, quindi vale la pena mappare le applicazioni IBM comuni all'ambiente di cui hanno bisogno. Le macchine IBM Aibim servono i mercati farmaceutico, alimentare e delle bevande e cosmetico, e la dimensione del contenitore spazia da 3 ml a 1000 ml.
Farmaceutico e medicale
Pharmaceutical bottles, oral-liquid bottles, and eye-drop vials are the strictest case. Eye-drop vials in the 3 to 30 ml range are typically run on the IBM55 Hybrid inside a Grade D clean area with oil-free air and filtered make-up air, because the drop must stay sterile at the neck. Oral-liquid and general pharmaceutical bottles in the 30 to 150 ml range are usually run on the IBM65 under the same cleanliness thinking. The neck finish from IBM is precise and flash-free, which helps the cap seal, but the surrounding air must not contaminate that finish.
Cosmetici e cura personale
Cosmetic vials and small personal-care jars from about 10 to 100 ml are run on the IBM55 or IBM65. Cosmetic plants often choose a filtered, temperature-controlled room rather than a full Grade D clean area, because the product is not sterile but the brand still demands a clean, glossy shoulder with no particles. The IBM process suits this well because the bottle is handled in an oriented, enclosed transfer rather than dropped on a belt.
Integratori alimentari e chimica di uso quotidiano
Health-supplement bottles from about 100 to 1000 ml are a natural fit for the IBM75, often in a general but tidy workshop with good ventilation. Daily-chemical small packs such as shampoo and lotion sample bottles are similar: the grade is general, the priority is output and neck consistency, and the air system can be a quality filtered compressor rather than oil-free medical-grade. The difference between these industries is therefore not the machine but the cleanliness discipline around it.
Tabella dei requisiti per modello e configurazione dell'officina
The table below links a typical requirement to a recommended Aibim model, the machine count, the cleanliness grade, and the resulting workshop area, power, cooling, and air configuration. Use it as a starting layout, then refine the numbers with Aibim against your confirmed machine ratings and local ancillaries.
| Requirement scenario | Recommended model | Units | Cleanliness grade | Workshop area | Power supply | Cooling and air |
|---|---|---|---|---|---|---|
| Eye-drop vials 3 to 30 ml, high volume | IBM55 Hybrid | 6 | ISO Class 8 / Grade D | 300 to 360 m² | 250 kVA transformer | 2 chillers about 20 kW; 2 oil-free receivers about 1 m³ at 0.8 MPa |
| Oral-liquid and pharma bottles 30 to 150 ml | IBM65 | 3 | ISO Class 8 / Grade D | 150 to 180 m² | 160 kVA transformer | 1 chiller about 25 kW; 1 oil-free receiver about 0.6 m³ |
| Cosmetic vials 10 to 100 ml | IBM65 / IBM55 | 3 | Filtered, temp-controlled | 120 to 160 m² | 125 kVA transformer | 1 chiller about 20 kW; 1 receiver about 0.6 m³ |
| Daily-chemical small packs 50 to 500 ml | IBM75 | 1 to 3 | General ventilation | 60 to 160 m² | 80 to 160 kVA | 1 chiller 15 to 30 kW; receiver about 0.6 m³ |
| Health-supplement bottles 100 to 1000 ml | IBM75 | 3 | General, Grade D optional | 150 to 180 m² | 160 kVA transformer | 1 chiller about 30 kW; receiver about 0.6 m³ |
This table intentionally separates the machine choice from the workshop grade. Two plants making the same bottle on the same IBM65 can need very different areas and air specs because one ships to a regulated market and the other does not. Set the grade from the product, then size the room and utilities to that grade.
Checklist pre-installazione prima del primo avvio
The single most useful document for a smooth commissioning is a pre-installation checklist completed before the truck arrives. Aibim reviews your workshop drawings against this checklist, and the Yes-No columns below are the ones to verify on site. Resolve every No before start-up; a missing ground or a weak chiller turns a one-day commissioning into a two-week delay.
| Category | Check item | Target | Yes / No |
|---|---|---|---|
| Electrical | Correct regional voltage and frequency supplied | 380 to 415 V 50 Hz or as ordered | |
| Electrical | Transformer and cable sized for installed plus ancillaries | Per Aibim confirmed rating | |
| Electrical | Ground resistance measured | 4 ohms or below | |
| Electrical | UPS on PLC and HMI supply | Fitted | |
| Water | Chiller capacity matches total heat rejection | 8 to 15 °C supply | |
| Water | Flow per machine available at the inlet | 18 to 30 L/min per model | |
| Water | Loop water quality controlled | pH 7.0 to 8.5, low hardness | |
| Air | Blow pressure at the ring | 0.8 MPa stable | |
| Air | Purity for product contact | Oil-free, dew point minus 20 to minus 40 °C, 0.01 mg/m³ oil | |
| Floor | Slab strength and flatness | 10 to 14 kPa, flat surface | |
| Floor | Oil-resistant, slip-resistant finish | Confirmed | |
| Space | Side and mold-opening clearance | 800 to 1200 mm sides, 1500 mm opening | |
| Space | Clear ceiling height and lifting path | 3.2 to 3.6 m, hoist or crane sized | |
| Environment | Temperature and humidity | 18 to 28 °C, 45 to 65 percent RH | |
| Environment | Cleanliness grade built where required | ISO Class 8 / Grade D if regulated | |
| Personnel | Trained operator and lockout knowledge | Training completed | |
| Personnel | Emergency stop and escape route verified | Marked and clear |
Consegnare la checklist completata ad Aibim prima della spedizione. Accorcia installazione e messa in servizio, previene le sorprese comuni e fornisce a entrambe le parti una baseline firmata di ciò che l'officina ha promesso di consegnare.
Assistenza e supporto per una messa in servizio fluida
Aibim, in quanto stabilimento Wanplas, supporta la macchina con gli impegni di servizio condivisi del gruppo, così il piano dell'officina sopra riportato è accompagnato dal supporto dopo la consegna. L'obiettivo è che la linea raggiunga rapidamente la produzione nominale e vi rimanga.
Prima e durante la consegna
Every machine is tested before shipment so the utilities and the process are verified at the factory, not discovered at your site. Aibim reviews your workshop drawings and the pre-installation checklist, then dispatches engineers for installation and commissioning on site. Because Aibim runs its own CNC machining center, critical parts are made and matched in-house, which shortens lead time and keeps the spare-part fit precise.
Ricambi, formazione e supporto remoto
The Wanplas group policy supplies USD 500 free parts every year, and warranty covers defective parts within the agreed period. Aibim trains your operators and maintenance staff on the line, the mold change, and the lockout procedure, and offers remote monitoring of the PLC so faults can be analyzed from the factory without a long on-site wait. The open-factory policy welcomes you to visit the 2022 plant, see the CNC center, and inspect the workshop-standard machines before you commit.
La revisione del workshop pre-avvio
As part of commissioning, Aibim conducts a pre-start workshop condition review using the same seven categories in the checklist above: electrical, water, air, floor, space, environment, and personnel. This is the moment to catch a borderline ground, a slightly small chiller, or a missing oil-free air spec before production begins. Treat it as the final gate between a delivered machine and a running line.
Domande frequenti
Quale alimentazione elettrica richiede una macchina Aibim IBM?
Most Aibim IBM machines are built for three-phase 380 to 415 V at 50 Hz, which is the default for China, much of Asia, and parts of Europe. The machines can also be configured for 220 to 240 V or 480 V at 60 Hz for the Americas and for 200 V at 60 Hz for Japan. The installed power ranges from about 22 kW on the IBM55 Hybrid up to about 32 kW on the IBM75, while the actual running load sits at roughly 55 to 75 percent of installed power because servo drives and the PREFILL hydraulic system do not draw full current continuously.
Quanto spazio a pavimento serve per una macchina IBM?
A single IBM machine needs about 40 to 60 square meters of workshop area when you include the machine footprint, operator and maintenance clearance of at least 800 to 1200 mm on the sides and 1500 mm at the mold-opening side, plus space for a small mold rack, a raw-material pallet, and finished-goods staging. Three machines typically need 120 to 180 square meters, and a six-machine line needs roughly 240 to 360 square meters once you add aisles, quality control, and buffer storage.
Le bottiglie IBM richiedono una camera bianca?
It depends on the end use. Cosmetic vials and daily-chemical small packs can be made in a general, well-ventilated workshop. Pharmaceutical bottles, eye-drop vials, and oral-liquid bottles for regulated markets usually require a controlled environment aligned with ISO 14644 Class 8 thinking and a Grade D clean-area concept, with positive pressure of about 5 to 10 Pa, controlled temperature and humidity, and filtered air. Aibim can advise the grade that matches your product and market.
Quale pressione e qualità dell'aria compressa richiede la funzione di soffiaggio?
The blow function on an IBM machine normally needs 0.6 to 1.0 MPa, with most Aibim configurations designed around 0.8 MPa. Pneumatic consumption is modest, about 0.4 to 0.6 cubic meters per minute depending on model. For pharmaceutical and food-contact products the air should be oil-free, dried to a dew point of minus 20 to minus 40 degrees Celsius, and filtered to an oil content near 0.01 milligrams per cubic meter, which is the medical-grade threshold.
Perché un sistema idraulico PREFILL è rilevante per il piano di alimentazione del mio laboratorio?
Aibim uses a PREFILL technology and variable-displacement pump pressurizing method in the hydraulic circuit. This means the pump only delivers the flow the process needs at each moment, so the actual running power stays well below the installed rating. That lowers the transformer and cable size you must provision and reduces heat rejected into the workshop, which in turn reduces the air-conditioning load.
Aibim può aiutarmi a verificare il mio laboratorio prima della consegna?
Yes. Aibim runs a pre-installation checklist covering power, water, air, floor, space, environment, and personnel, and reviews your workshop drawings before shipment. The factory also performs testing before delivery, provides installation and commissioning, supplies USD 500 free parts every year, trains operators, offers remote monitoring of the PLC, and welcomes an open-factory visit so you can inspect the workshop-standard machines directly.
Quale capacità di raffreddamento dovrei pianificare per una linea IBM?
Cooling serves the hydraulic oil, the mold-temperature circuits, and the barrel and plasticizing zones. Aibim specifies cooling-water flow per model, from about 18 L/min on the IBM55 Hybrid to about 30 L/min on the IBM75, at a supply temperature of 8 to 15 degrees Celsius. Size the chiller from the total heat rejection, which is roughly the running power plus a margin for the dryer and ancillaries, and always insulate the supply and return lines to protect the set temperature.
Quale resistenza del pavimento e altezza del soffitto richiede una macchina IBM?
The machine weight is about 6.8 to 9.8 tons depending on model, spread over a footprint so the floor loading is in the range of 10 to 14 kPa for a standard reinforced concrete slab. The floor should be flat, oil-resistant, and slip-resistant. The clear internal height should exceed the machine height plus the hopper and loader, usually about 3.2 to 3.6 meters, with a lifting device such as a hoist or overhead crane sized for the machine weight to handle unloading and mold changes.
Conclusione
Aibim, a Wanplas factory with more than 12 years of plastic machinery experience, its own CNC machining center, a 2022 new plant, and an annual capacity above 100 machines, builds three-station, one-step IBM machines for containers from 3 ml to 1000 ml. The machine is only half of the result; the workshop around it decides whether the rated output, the precise neck finish, and the required cleanliness are actually achieved. This guide has covered the power supply from voltage standard to transformer sizing, the floor area and layout from single cell to six-machine line, the floor and foundation, the ceiling and lifting, the cooling and compressed-air systems, the temperature and cleanliness grades by industry, ventilation and noise, material handling, and safety, closing with the model and configuration table, the pre-installation checklist, and the service that backs it all.
If you are planning a new IBM line or upgrading an existing one, send Aibim your workshop drawings and your target products. The engineering team will review the layout, confirm the model choice between the IBM75, IBM65, and IBM55 Hybrid, and return a utility and workshop configuration proposal covering power, cooling, air, floor, and cleanliness so your line starts up fast and stays stable. Aibim welcomes a visit to the factory to walk through the machines and the standards described here before you place the order.