Introduction : pourquoi le calcul de la capacité guide votre décision d'achat
Accurate injection blow molding machine capacity calculation is the single most important step before you invest in a production line for pharmaceutical, cosmetic, or food small bottles. The headline number a supplier quotes is meaningless until you understand the formula behind it: how the cycle time, the number of mold cavities, the hours you actually run each day, and your real equipment effectiveness combine into a daily and yearly bottle count. This article gives you the exact equations, walks through two fully worked examples on real Aibim machines, and shows you how to translate a target output into a concrete machine and mold specification.
Aibim, a Wanplas factory with more than 12 years of experience in injection blow molding and machines running in over 40 countries, builds the IBM55 Hybrid Electric, IBM65, and IBM75 series for containers from 3 ml to 1000 ml. Those three models cover the full range of small-bottle production, and every capacity figure in this guide is built around their real operating envelope. Whether you make 5 ml oral-dose vials, 30 ml cosmetic jars, or 500 ml pharmaceutical shampoo bottles, the same formulas apply, only the input values change.
By the end of this guide you will be able to calculate theoretical hourly output, adjust it with an OEE factor, project daily and yearly volume, size the right cavity count, and estimate energy use in kilowatt-hours per 1,000 bottles. You will also see where most capacity estimates go wrong, and how to avoid quoting a number your line can never reach. No currency figures are used; all cost framing is shown as relative tiers and all output is expressed in physical units such as bottles per hour or kilowatt-hours per 1,000 bottles.
Comment une machine de moulage par injection-soufflage produit des bouteilles
Injection blow molding is a one-step, three-station hollow molding process. Plastic raw material is first plasticized in the barrel by a reciprocating screw, then injected into a cavitated preform or parison mold at the injection station. The parison is a precisely shaped tube with the finished bottle neck already molded in. A rotating transfer system carries the hot parison to the blow station, where compressed air expands it against the cooled blow cavity to form the bottle. A final transfer moves the finished bottle to the ejection station, where it is stripped and the neck is held by a long-distance digital laser sensor for safe, flash-free removal.
Because the three stations operate in parallel rather than in sequence, one cycle of the machine completes one bottle per cavity, but the wall-clock time of a cycle is set by the slowest station. In practice the blow-and-cool station almost always governs the cycle, because the molten parison must cool enough to hold its shape before ejection. This parallel architecture is why an injection blow molding machine can deliver a finished, flash-free bottle with no post-molding trim operation, and why cycle time is so sensitive to bottle wall thickness and cooling efficiency.
The materials processed on Aibim machines include polyethylene (HDPE, LDPE, LLDPE), polypropylene, polystyrene, ABS, SAN, TPU, PC, and PCTG. Each has a different melt viscosity and cooling rate, which shifts the cycle time. Polypropylene and HDPE cool relatively quickly; polycarbonate and PCTG need longer cooling, so for the same bottle size the cycle will be longer and the achievable hourly output lower. When you calculate capacity, always anchor the cycle time to the actual material, not a generic average.
The three-station design also explains why injection blow molding is favored for pharmaceutical, cosmetic, and food small bottles: the bottle neck and thread are molded to tight tolerance at the injection stage, so there is no flash to trim and no contamination route from a secondary operation. That cleanliness is part of the value, but it does not change the math. Output still equals cycles per hour times cavities, adjusted for how well the line actually runs.
La formule maîtresse de capacité : le temps de cycle rencontre les cavités
Chaque chiffre de production en moulage par injection-soufflage remonte à une relation maîtresse. La production horaire théorique est le nombre de cycles que la machine peut accomplir en une heure, multiplié par le nombre de bouteilles conformes produites par cycle.
Cette formule répond à la question « combien de bouteilles la machine peut-elle théoriquement produire en une heure si elle ne s'arrête jamais et si chaque cavité réussit toujours ». C'est le plafond, pas la réalité. Pour passer du plafond à un nombre autour duquel vous pouvez planifier la production, vous multipliez par un facteur d'efficacité.
À partir du taux horaire effectif, la production journalière et annuelle découle directement du nombre d'heures et de jours de fonctionnement.
Réunis, la chaîne complète est :
Cette chaîne unique est l'épine dorsale de chaque estimation dans le reste de l'article. La compétence de la planification de la capacité n'est pas l'arithmétique, qui est simple, mais le choix de valeurs réalistes pour t_c, N, OEE, H et D. Les sections suivantes vous montrent comment définir chacune avec des chiffres concrets sur de vraies machines Aibim.
Anatomie du temps de cycle IBM
The cycle time t_c is the wall-clock seconds for one full rotation of the three-station machine. Because stations run in parallel, t_c equals the longest single-station time, not the sum of all three. Understanding the breakdown lets you see where a cycle can be shortened and where it is physically fixed by cooling.
| Station or phase | What happens | Typical time (seconds) | Usually gating? |
|---|---|---|---|
| Poste d'injection | Plasticize and inject parison, then screw recovery | 2.0 to 3.5 | No (overlaps next) |
| Blow and cool station | Air blow, wall cooling, shape set | 4.5 to 11.0 | Yes (slowest) |
| Ejection and transfer | Stripping, laser safety check, index | 1.2 to 2.0 | No |
| Resulting machine cycle | Set by the longest station | 8 to 16 | Reference |
In this breakdown the blow-and-cool station dominates. For a 100 ml HDPE bottle the cooling might be 6 seconds; for a 500 ml PCTG bottle it can stretch past 10 seconds because more mass must solidify. Screw recovery at the injection station often overlaps the cooling at the blow station, which is exactly why the parallel layout keeps the cycle near the blow time instead of adding all phases together.
Two practical levers shorten t_c. First, optimize cooling with chilled mold temperature control and, where the material allows, a thinner controlled wall, because cooling time scales with wall thickness squared in simplified heat-transfer terms. Second, use a machine with strong, stable clamping and fast indexing so the transfer and ejection phases stay short. Aibim’s single-crossbeam double-pole clamping framework and enlarged mold space are built to keep those non-cooling phases minimal.
Exemple concret 1 : Production quotidienne de l'Aibim IBM75
Calculons la production quotidienne d’une Aibim IBM75 produisant une bouteille pharmaceutique en HDPE de 100 ml sur un moule à 6 empreintes, fonctionnant deux équipes plus une troisième équipe partielle pour un total de 22 heures d’exploitation par jour. Nous construirons le chiffre étape par étape afin que vous puissiez substituer vos propres valeurs plus tard.
Étape 1, réglez le temps de cycle. Pour une bouteille HDPE de 100 ml, la station de soufflage et refroidissement gouverne à environ 12 secondes, avec l'injection et l'éjection se chevauchant dans cette fenêtre. Donc t_c = 12 s.
Étape 2 : appliquer la formule maîtresse pour le rendement horaire théorique.
Étape 3, appliquez l'OEE. Supposons que la ligne fonctionne avec une disponibilité de 0,92, une performance de 0,95 et une qualité de 0,99. OEE = 0,92 x 0,95 x 0,99 = 0,865. C'est un chiffre sain et réaliste pour une ligne pharmaceutique bien gérée.
Étape 4, multipliez par les heures de fonctionnement.
So this configuration delivers about 34,250 finished 100 ml bottles every day. If you ran only a single 8-hour shift, the same machine would produce roughly 12,456 bottles per day, which shows how strongly the operating-hours input drives the result. The table below summarizes the sensitivity of daily output to the shift pattern, holding cycle, cavities, and OEE constant.
| Operating hours per day (H) | Shift pattern | Daily output (bottles) | Relative to 24 h |
|---|---|---|---|
| 8 | Single shift | 12,456 | 0.33 |
| 16 | Double shift | 24,912 | 0.66 |
| 20 | Double shift plus buffer | 31,140 | 0.83 |
| 22 | Near-continuous | 34,254 | 0.91 |
| 24 | Continuous | 37,368 | 1.00 |
Notice that moving from 22 to 24 hours adds only about 9 percent output but removes the planned downtime window used for mold changes and preventive maintenance. Most producers choose 20 to 22 hours to keep that buffer, which is why the 22-hour figure is a sensible planning baseline rather than the maximum.
Exemple concret 2 : production annuelle et planification de la capacité
Étendons maintenant l'exemple de l'IBM75 à une année complète et comparons-le à un scénario de petites bouteilles à cavités plus nombreuses sur l'IBM55 Hybrid Electric. La production annuelle répond à la question qui intéresse réellement un responsable d'usine : cette ligne peut-elle satisfaire la demande annuelle ?
Prenez l'IBM75 à 34 254 bouteilles par jour et faites-la fonctionner 300 jours ouvrables par an (en tenant compte des jours fériés, de la maintenance planifiée et des périodes de faible demande).
Cela représente environ 10,3 millions de bouteilles de 100 ml par an avec une seule IBM75 équipée d'un moule à 6 cavités. Considérons maintenant l'IBM55 Hybrid Electric produisant des flacons pharmaceutiques PP de 15 ml sur un moule à 12 cavités avec un cycle rapide de 8 secondes, fonctionnant 24 heures avec un OEE de 0,85.
The hybrid electric small-vial line therefore delivers roughly 36.4 million bottles per year, more than three times the IBM75 figure, driven by the higher cavity count and shorter cycle rather than by a bigger machine. This contrast is the central lesson of capacity planning: for small bottles, cavities and cycle time dominate, while for large bottles, cooling time and lower cavity counts cap the rate no matter how many machines you buy.
| Scenario | Model | Cavities | Cycle (s) | OEE | Yearly output |
|---|---|---|---|---|---|
| 100 ml HDPE, 300 d, 22 h | IBM75 | 6 | 12 | 0.865 | 10.28 million |
| 15 ml PP, 330 d, 24 h | IBM55 Hybrid | 12 | 8 | 0.85 | 36.35 million |
| 250 ml PP, 300 d, 20 h | IBM65 | 8 | 11 | 0.82 | 19.07 million |
When you plan capacity, build the yearly figure first from demand, then work backward to the model and cavity count. If annual demand is 20 million 250 ml bottles, the IBM65 row above already meets it; if demand is 40 million 15 ml vials, you would need roughly two IBM55 Hybrid lines or one line run at higher OEE and longer hours. Capacity planning is always a backward calculation from the demand target.
OEE : disponibilité, performance et qualité
Le taux de rendement global (OEE) est la discipline qui transforme un maximum théorique en un chiffre auquel vos équipes de finance et de production peuvent se fier. L'OEE est le produit de trois ratios indépendants, chacun de 0 à 1.
Availability captures unplanned stops and planned downtime such as mold changes. A line planned for 22 hours but actually running 20.2 hours due to a 1.8-hour mold change has availability of 20.2 / 22 = 0.918. Performance captures speed loss: if the machine should run at a 12-second cycle but averages 12.6 seconds because of minor slowdowns, performance is 12 / 12.6 = 0.952. Quality captures scrap: if 1 percent of bottles are rejected for short shots or visual defects, quality is 0.99.
Multipliez-les et OEE = 0,918 x 0,952 x 0,99 = 0,865, exactement le chiffre utilisé dans l'exemple de l'IBM75. Le tableau ci-dessous montre comment les niveaux d'OEE modifient la production effective pour un débit théorique fixe de 1 800 bouteilles par heure.
| OEE tier | Typical meaning | Effective bottles per hour | Loss vs theoretical |
|---|---|---|---|
| 0.60 | Poor, frequent stops | 1,080 | 40% |
| 0.75 | Average, typical SME | 1,350 | 25% |
| 0.85 | Good, well-run line | 1,530 | 15% |
| 0.90 | Excellent, world class | 1,620 | 10% |
The gap between a 0.60 line and a 0.90 line is 50 percent more output from the identical machine. That is why Aibim emphasizes pre-shipment testing, remote monitoring of PLC data, and rapid spare-parts support: those services attack the availability and performance losses that quietly destroy quoted capacity. When a supplier quotes output, always ask which OEE assumption sits behind it.
Série de machines Aibim IBM et spécifications réelles
Aibim’s three production models share the same three-station one-step architecture, PREFILL hydraulic technology, and CE-certified safety system, but they are sized for different bottle volumes and cavity counts. The specification tables below use the standard technical envelope of each series; exact values should be confirmed against the factory quotation for your specific mold and material. All three are built in Aibim’s own CNC center, which supports tight tolerances on clamping and transfer that protect cycle-time stability.
Machine de moulage par injection-soufflage hybride électrique IBM55
L'IBM55 Hybrid Electric combine une fermeture servo-hydraulique avec des entraînements électriques auxiliaires pour atteindre des cycles rapides sur les petites bouteilles tout en réduisant la consommation d'énergie. C'est la base idéale pour la production de fioles et d'échantillons à haute cavité.
| Parameter | IBM55 Hybrid Electric |
|---|---|
| Force de serrage | 55 tons (540 kN) |
| Screw diameter | 35 mm |
| L/D ratio | 20:1 |
| Container volume range | 3 ml to 100 ml |
| Max neck diameter | 38 mm |
| Max cavities | 14 |
| Typical cycle time | 6 to 9 seconds |
| Installed power | 14.5 kW |
| Poids de la machine | about 4.8 t |
Machine de moulage par injection-soufflage IBM65
L'IBM65 est le cheval de bataille milieu de gamme pour les flacons cosmétiques et pharmaceutiques de 50 à 350 ml, équilibrant le nombre de cavités et l'espace de serrage pour les formats de petits flacons les plus courants.
| Parameter | IBM65 |
|---|---|
| Force de serrage | 65 tons (640 kN) |
| Screw diameter | 40 mm |
| L/D ratio | 20:1 |
| Container volume range | 3 ml to 350 ml |
| Max neck diameter | 45 mm |
| Max cavities | 10 |
| Typical cycle time | 8 to 13 seconds |
| Installed power | 21 kW |
| Poids de la machine | about 6.5 t |
Machine de moulage par injection-soufflage IBM75
L'IBM75 est le plus grand de la série, conçu pour des bouteilles de 350 à 1000 ml où un nombre réduit d'empreintes et un refroidissement plus long sont inévitables, mais où la précision du col du moulage par injection-soufflage reste requise.
| Parameter | IBM75 |
|---|---|
| Force de serrage | 75 tons (735 kN) |
| Screw diameter | 45 mm |
| L/D ratio | 20:1 |
| Container volume range | 3 ml to 1000 ml |
| Max neck diameter | 55 mm |
| Max cavities | 8 |
| Typical cycle time | 10 to 18 seconds |
| Installed power | 28 kW |
| Poids de la machine | about 8.5 t |
The screw diameter and L/D ratio determine plasticizing capacity; for these small-bottle machines a 20:1 L/D with a 35 to 45 mm screw supplies more than enough melt for the parison without over-residence time that could degrade heat-sensitive resins. The clamping force scales with bottle area and blow pressure, and the figures above leave comfortable margin for stable molding at the stated cavity counts.
Nombre de cavités et sélection du volume de la bouteille
Cavity count is the strongest lever you control after choosing the model. More cavities multiply output directly, but each cavity adds cooling load and mold cost, and very large bottles physically cannot fit many cavities in the platen. The table below maps typical bottle volumes to a sensible cavity count and the resulting cycle on Aibim machines.
| Bottle volume | Recommended model | Typical cavities | Typical cycle (s) | Theoretical per hour |
|---|---|---|---|---|
| 3 to 15 ml | IBM55 Hybrid | 12 to 14 | 6 to 8 | 5,400 to 6,300 |
| 15 to 50 ml | IBM55 Hybrid / IBM65 | 10 to 12 | 7 to 10 | 3,600 to 5,100 |
| 50 to 150 ml | IBM65 | 8 to 10 | 9 to 12 | 2,400 to 3,000 |
| 150 to 350 ml | IBM65 / IBM75 | 6 to 8 | 11 to 14 | 1,540 to 2,180 |
| 350 to 1000 ml | IBM75 | 4 to 6 | 14 to 18 | 800 to 1,540 |
To pick cavities, start from your required effective hourly output, divide by your expected OEE and by 3,600 divided by the cycle, then round to the nearest practical cavity count the model supports. For example, if you need 3,000 good 80 ml bottles per hour at OEE 0.85, you need theoretical 3,529 per hour; at a 10-second cycle that is 9.8 cavities, so choose a 10-cavity mold on the IBM65. The calculation is reversible, which is exactly why it is so useful during quotation.
Consommation d'énergie : kilowattheures pour 1 000 bouteilles
L'énergie est un coût lié à la capacité que les acheteurs pèsent de plus en plus aux côtés du débit. Exprimez-le en kilowattheures pour 1 000 bouteilles afin qu'il évolue proprement avec la production et qu'il soit indépendant de la monnaie.
Pour l'IBM75 à 1 557 bouteilles effectives par heure et une consommation réelle d'environ 17 kW (environ 60 pour cent de la puissance installée de 28 kW en charge normale avec la technologie PREFILL), le chiffre est :
Pour l'IBM55 Hybride à 4 590 bouteilles effectives par heure et une consommation d'environ 9 kW (bien en dessous de la puissance installée de 14,5 kW grâce à la conception hybride électrique) :
La ligne hybride électrique pour petites bouteilles est nettement plus économe en énergie par bouteille, car elle produit beaucoup plus de bouteilles par kilowatt-heure. Le tableau ci-dessous compare les trois modèles sur une base de 1 000 bouteilles à des charges représentatives.
| Model | Effective bottles per hour | Approx. running power (kW) | kWh per 1,000 bottles | Energy tier |
|---|---|---|---|---|
| IBM55 Hybrid | 4,590 | 9 | 1.96 | Low |
| IBM65 | 2,600 | 13 | 5.00 | Medium |
| IBM75 | 1,557 | 17 | 10.9 | Medium |
Aibim’s PREFILL technology and variable displacement pump pressurizing in the hydraulic system are the reason these running powers sit well below the installed ratings, targeting at least 35 percent energy saving against conventional hydraulic units. When you compare machines, always ask for the running power at your cycle and cavity count, not the nameplate installed power, because the gap between the two is where the real saving lives.
Tableau de recommandations de sélection
Le tableau ci-dessous convertit directement les exigences de production courantes en un modèle Aibim recommandé et un point de départ de cavités. Utilisez-le comme premier filtre, puis exécutez la formule complète avec votre propre cycle et OEE pour confirmer le chiffre quotidien et annuel.
| Requirement | Recommended model | Cavities | Target daily output |
|---|---|---|---|
| 5 to 15 ml pharma vials, high volume | IBM55 Hybrid Electric | 12 to 14 | 90,000 to 110,000 |
| 20 to 50 ml cosmetic jars | IBM55 Hybrid / IBM65 | 10 to 12 | 55,000 to 85,000 |
| 50 to 150 ml food and pharma | IBM65 | 8 to 10 | 40,000 to 55,000 |
| 150 to 350 ml shampoo or lotion | IBM65 / IBM75 | 6 to 8 | 28,000 to 40,000 |
| 350 to 1000 ml wide-mouth bottles | IBM75 | 4 to 6 | 14,000 to 30,000 |
If your target daily output sits between two rows, choose the larger model for headroom, because running a smaller machine at its absolute maximum cycle leaves no buffer for OEE losses. Aibim engineers can confirm the exact mold cavity layout and verify the cycle on your material during pre-shipment testing.
Erreurs courantes dans l'estimation de la capacité
La plupart des résultats de capacité décevants proviennent d'une poignée d'erreurs répétées. Le tableau ci-dessous les énumère avec la correction, afin que vous puissiez vérifier tout devis que vous recevez.
| Mistake | Why it hurts | Correction |
|---|---|---|
| Quoting theoretical max only | Ignores stops and scrap, overstates by 15 to 40 percent | Always multiply by a realistic OEE of 0.75 to 0.85 |
| Using 24 h every day | Leaves no maintenance or changeover window | Plan 20 to 22 h per day, 300 to 330 days per year |
| Generic cycle time | Cooling differs by material and wall | Anchor t_c to your material and bottle on a trial |
| Counting cavities not feasible | Platen or clamping cannot fit the count | Match cavities to model clamping and mold space |
| Confusing installed and running power | Overstates energy cost per bottle | Use measured running power in kWh per 1,000 bottles |
Aucune de ces erreurs ne modifie la formule ; elles corrompent seulement les entrées. La discipline sur les entrées est ce qui distingue un devis fiable d'un devis optimiste.
Industries d'application des machines IBM Aibim
Les machines Aibim sont construites pour les petites bouteilles de haute précision sans bavures où la précision du col et la propreté importent plus que le volume maximal. Les véritables domaines d'application du profil de l'usine sont les produits pharmaceutiques, l'alimentation, les boissons et les cosmétiques, et chacun correspond à des produits finis spécifiques.
In pharmaceuticals, the bottles are oral-dose vials, eye-drop bottles, nasal spray actuators, and small dropper containers, typically 3 to 100 ml in HDPE, PP, or cyclic olefin and COP-like materials where the molded neck guarantees a leak-tight closure. In food and drink, the products are single-serve sauce cups, honey and syrup bottles, flavored-milk shot bottles, and condiment containers where the one-step process avoids post-mold trimming that could introduce foreign particles. In cosmetics, the dominant formats are 15 to 100 ml cream jars, serum bottles, and sample vials in PP, PS, SAN, and PCTG where surface finish and thread quality drive shelf appeal.
Because the three-station process holds the neck to injection-molded tolerance, these bottles meet the hygiene expectations of pharmaceutical and food lines without secondary operations. For regulated markets, the materials and machine surfaces should be specified to relevant standards such as FDA food-contact and ISO 10993 biocompatibility where applicable, and the machine carries CE certification with a light curtain and laser safety sensor at the stripper station.
Installation, mise en service et maintenance
Capacity is only realized if the machine is installed and maintained so it actually runs at the assumed OEE. Aibim supports installation and commissioning by engineers who set the machine on the prepared foundation, connect utilities, level the frame, and run the first production cells on the customer mold and material. Commissioning includes verifying the actual cycle time, recording the first stable hourly output, and documenting the baseline OEE so later losses are visible.
Routine maintenance that protects capacity includes screw and barrel wear inspection on the plasticizing unit, hydraulic oil analysis on the clamping system, mold cooling-channel descaling to keep cycle time short, and calibration of the blow air and stripper laser sensor. Because Aibim runs its own CNC center for machine parts, wear items and spare molds can be reproduced to original tolerance, which shortens any downtime. The SD card parameter storage lets a proven recipe be copied across machines, reducing changeover time that would otherwise erode availability.
Service et support
Aibim, as a Wanplas factory, extends the group’s shared service promises to every IBM line. The Wanplas brand commits to USD 500 free parts every year for the covered line, free replacement of damaged parts within the warranty, and an open-factory policy that welcomes customer visits for inspection and audit before and after purchase. Wanplas, with its network of specialized factories, backs these promises with a track record of 100+ lines per year from Aibim alone and machines running in 40+ countries.
Support also covers pre-shipment testing on the customer’s mold and material so the quoted daily and yearly output reflects measured performance, on-site installation and commissioning, operator training on setup and maintenance, and remote operation and maintenance through PLC data monitoring that lets engineers check running status and respond to abnormal feedback. These services directly defend the availability and performance components of OEE, which as shown earlier can mean the difference between 1,080 and 1,620 effective bottles per hour on the same machine.
Questions fréquemment posées
Quelle est la formule de base pour la production d'une machine de moulage par injection-soufflage ?
The theoretical hourly output equals 3,600 divided by the cycle time in seconds, multiplied by the number of cavities. In symbols: Q_theoretical = 3,600 / t_c x N. Multiply by an overall effectiveness factor (OEE) and the operating hours per day to get the daily figure, then by operating days per year for the yearly figure.
Comment estimer le temps de cycle d'une machine IBM à trois postes ?
A three-station one-step IBM machine runs injection, blow, and ejection in parallel, so the cycle is gated by the longest station, almost always the blow-and-cool station. Add the parison injection time, the blow-and-cool time, and the transfer or ejection time; the station that takes the longest sets the machine cycle. Larger bottles need longer cooling and therefore a longer cycle.
Pourquoi le TRS est-il plus important que le rendement maximal théorique ?
Theoretical output assumes the machine never stops and every cavity always produces a good bottle. Real lines lose time to mold changes, material changeovers, minor faults, speed loss, and scrap. OEE multiplies availability, performance, and quality, and a realistic OEE of 0.75 to 0.85 typically cuts the theoretical number by 15 to 25 percent. Capacity planning should always use the OEE-adjusted figure.
Combien de cavités dois-je choisir pour un volume de bouteille donné ?
Cavity count trades against bottle size and cooling demand. Small volumes such as 3 to 30 ml pharmaceutical vials support 10 to 14 cavities, mid volumes such as 50 to 250 ml support 6 to 10 cavities, and large volumes up to 1000 ml support 4 to 8 cavities. The right number keeps the cycle short while staying within the clamping force and mold space of the chosen model.
Comment la consommation d'énergie est-elle calculée pour une ligne IBM ?
Measure the actual running power in kilowatts during stable production, then divide by the effective hourly output and multiply by 1,000 to get kilowatt-hours per 1,000 bottles. Aibim machines with PREFILL hydraulic technology and variable displacement pumps are engineered to save at least 35 percent energy against conventional hydraulic units, which directly lowers this figure.
Quel modèle Aibim convient à un objectif de production quotidien moyen ?
For a target around 30,000 to 45,000 bottles per day of 50 to 250 ml containers, the IBM65 is a balanced choice with up to 10 cavities and an 8 to 13 second cycle. For smaller high-volume vials the IBM55 Hybrid Electric reaches higher cavity counts, while the IBM75 covers larger 350 to 1000 ml bottles at lower cavity counts.
Dois-je planifier la capacité autour d'un fonctionnement de 24 heures ou moins ?
It depends on labor, utility cost, and demand stability. A single 8 hour shift gives roughly one third of a 24 hour plan, while a two-shift 22 hour plan captures most of the benefit with time reserved for mold changes and maintenance. Many pharmaceutical and cosmetic producers run 20 to 22 hours per day to balance output with planned downtime.
Quelle est la précision de ces calculs avant que j'achète une machine ?
The formulas are exact; the uncertainty sits in the input values. Cycle time, cavity count, and OEE should be confirmed by a real trial run on the actual mold and material. Aibim offers pre-shipment testing on the customer mold and material so the quoted daily and yearly output reflects measured performance rather than a textbook estimate.
Conclusion
Injection blow molding machine capacity calculation comes down to one dependable chain: yearly output equals 3,600 divided by cycle time, times cavities, times OEE, times operating hours per day, times operating days per year. The arithmetic is simple; the discipline is in the inputs. Anchor the cycle time to your real material and bottle, choose cavities the model can actually hold, apply a realistic OEE of 0.75 to 0.85, and plan 20 to 22 operating hours per day rather than a perfect 24. Do that and your quoted output will match what the line delivers.
Aibim’s IBM55 Hybrid Electric, IBM65, and IBM75 cover the full 3 ml to 1000 ml small-bottle range with the three-station one-step process, PREFILL hydraulic technology, and CE-certified safety that keep cycle times short and energy per 1,000 bottles low. If you are scoping a new line, send your bottle drawing, target daily or yearly volume, and material to the Aibim team for a tailored capacity calculation and a verified quotation, and schedule a factory audit or a trial run on your mold to confirm the numbers before you commit. The Wanplas group’s shared promises, including USD 500 free parts every year and an open-factory policy, support the line long after startup.
When you compare competing quotations, insist that every supplier states the cycle time, cavity count, assumed OEE, operating hours, and running power behind the headline number, because only then can two offers be compared on equal terms. A machine quoted at a higher theoretical rate but with a longer real cycle and weaker support may deliver fewer bottles per year than a modestly spec’d line that actually runs. Treat the formula in this article as your evaluation checklist, and let measured performance, not marketing language, decide the purchase.






